background

Biochemistry Analysers

Home // Products // Biochemistry Analysers

product

Nv-200 Fully Automated Biochemistry Analyzer

  • General information:--Machine type : Random access
    -Test speed : Constant 50 test/hour (Mono reagent or double reagent)
    -Test principle : Colorimetric method, Turbidimetry
    -Test method : 1 point end, 2 point end, Fixed-Time, Kinetics
    -Calibrator type : Linear & Non-linear
  • Reagent unit: Reagent tray : 40 reagent positions 40 for R1 & R2), Non-stop cooling system with peltier pad inside, 24 hours 2ºC to 14ºC.
    Reagent volume : 10-300µl, step by 1µl
  • Reaction unit: Reaction tray : 44 reaction cuvettes, new amorphous optical plastic reaction cups, perfect transmittance
    Reaction volume : 150µl-330µl
    Temperature : Heating coil incubation system, reaction temperature (37±0.1C)
  • Sample unit: Sample tray : 40 sample position
    Sample : Micro cup, sample cup, primary tube & blood collection tube (12-13)mm * (25-100)mm
    Sample volume : 2-30µl, step by 0.1µl
    Sample probe: Liquid surface detection, timely tracking for liquid volume. Collision Protection
  • Mixing system: Mixer : Paddle-type mixing, effective and reducing carryover
  • Optical system: : Light source : Halogen lamp
    Wavelength : 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm; 700nm (4 more options)
    Absorbance range : 0-4.0 Abs
    Resolution : 0.0001 Abs
  • Operating system: Operation system : Windows 7, Windows 8, Windows 10
    Report printing : 6 formats option, support custom formats
    Interface : pattern, TCP/IP network interface
  • Working conditions: Water consumption : 8L/hour (maximum)
    Dimension : 780mm * 565nm * 1120mm (L*W*H)
    Weight : 80kg
  • Power Supply: 220V ± 10%, 50/60 Hz, 2000VA,
    Earthing voltage < 5V online ups (230V) with isolated transformer 2KVA
product
Methods Absorbance End point with Standard / Factor Fixed time Kinetic Differential Coagulation Multipoint Up to 10 Standards
Principles Absorption Spectrophotometry
Measurement Range -0.1 to 3.0 Absorbance
Filters 340, 405, 505 , 546 , 578 , 630 and 700 nm interference type
Thermostat System Accuracy ± 0.1 °C Peltier regulated 25°C ,30 °C and 37° / RT
Programming Table of test:- Up to 235
  Table of Units:- Up to 9
  Memory:- 1000 Test Results
  Quality Control Storage:- Last 30 Results
Cuvettes Flow Cell of 18 or 32 Removable Cuvettes:- Macro , semi-micro and micro plastic or glass cuvettes
Light Source Halogen Lamp 12v/20W or 6v / 10W
Power / Dimensions Voltage: 110-220V / 50 -60 Hz
Power supply : <80 W
Temperature: 10 to 40 °C
Relative Humidity: 80 %
Dimensions: (45 x 41 x 17) cm
Quality Control 3 Controls Per Test – Low , Medium , Higher Levy Jennings Charts & Westgard’s Rules